The Brief


This school approached us with a view to securing the school with a complete gate automation and access control solution. The installation required a new fire door as well as Paxton Net2 access control to the new doors and the existing double doors near the hall.

They also requested a new Paxton Net2 access control solution to the front vehicle gate.

Fire Doors

We started by installing a new set of fire rated timber double doors and frame in the corridor to the left of the Reception area.

These fire rated, quarter glazed and fitted with push panels. They were finished in the colour of their choice.

We also installed a double Maglock to the top of each door with a P50 Proximity reader on entry and E50 Exit Button with re settable break-glass on exit.

Sign-in Systems

We went on to mount a Net2 Access Control unit with plastic housing at high level, local to the door. New and existing containment, colour-coded Cat5e connections to the nearest network cabinet were also installed. A new fused un-switched spur was installed at high level near the Paxton control unit and was run from the nearest fuse board.

The Paxton Net2 software was installed on a PC of their choice, from where we also installed a Desktop card reader. This is used for assigning cards/fobs to doors.

Cabling

We fitted the gate with an Intercom mounting post on the street side for vehicle access, which now houses a new Vandal resistant video Entry unit with weather-resistant hood and long-range proximity reader.

An underground sensor was installed under the drive for sensing vehicles on exit, allowing the gate to be opened.

3 x Paxton touch screen Video Entry phones were installed for controllability of the gate.

All power and data cabling was run from the main building to the gate via a trench. To excavate two no tracks across the main access road to allow for gate link and to allow for gate sensors.

Gate Automation

  • Re-positioning fence post which is located next to the RH gate.
  • Supplying and welding No 2 extended gate hooks/hinges as the existing ones were short and did not comply with new underground automation
  • 1 x double swing gate underground automation kit – 2 motor boxes, 2 motors, 1 control unit, 1 pair of safety photocells, 1 receiver and 2 transmitters
  • 1 x extra pair of safety photocells
  • 6 x resistive hard-wired safety edges
  • 1 x exit pressure pad
  • 1 x detector
  • 1 x maglock, 12v dc relay and 12vdc power supply
  • 1 x fireman switch (essential)
  • 1 x enclosure to fit gate controls